| General Data: |
|
| Direction of Rotation : |
Counter-Clockwise Viewed from Fan Blade |
| Air Flow Direction : |
Label Side |
| The Best Mounting Direction : |
In Any Orientation |
| Operating Temperature : |
-10 to +70 Deg.C |
| Storage Temperature : |
-40 to +70 Deg.C |
| Bering System : |
Precise Ball Bearing System or Lubricated Sintered Sleeve Bearing System |
| Tolerances : |
15% on Rated Power & Current |
| Insulation Resistance : |
More than 500M ohm between internal stator and lead wire(+) measured by DC 500V |
Dielectric Strength
(withstand voltage) : |
Applied AC 500V for one minute or AC 600V for two seconds between housing and lead wire(+) |
| Safety Protection : |
Electronic locked rotor protected |
| Vibration : |